Alarm Lists
Name ID (Hex) Description Source Default
Value
Operation Effect
Configuration
Mismatch
The configuration
settings of units in the 1
+ 1 redundancy group
may not match. To clear
this alarm, copy the
configuration settings
from one unit to the
other unit using buttons
on the Standalone 1 +
1 Redundancy
configuration settings to
copy the up-to-date
configuration settings to
the other unit.
Base
Unit
Major
Service will continue but
there is a mismatch in
configuration and the action
listed should be performed.
Redundant
Secondary
Active
The redundant
secondary is active. This
will be eroding the timed
license on the
secondary unit. Repair
the primary and switch
back to it as soon as
possible. To switch back
to the primary use the
button on the
Standalone 1 + 1
Redundancy
configuration settings.
Base
Unit
Major
Service is maintained but
the life of the secondary is
time limited (30 days).
Warnings will be given
before this deadline.
Version
Mismatch
The software version,
hardware configuration
or hardware version of
units in the 1 + 1
redundancy group are
not identical. The
secondary unit will not
be able to act as a
redundant spare. This
alarm will only be raised
on a secondary unit,
even though the
secondary may contain
the desired
configuration.
Base
unit
Major
This should be a set up
alarm and should be
resolved before a service
goes on air.
License Nearly
Expired
The 1 + 1 redundancy
backup license is close
to expiring. If it expires,
the secondary unit will
not be able to act as a
redundant spare.
Contact support to
renew the license.
Base
unit
Critical
Alarm to prompt action that
the secondary is running
out of time.