Alarm Lists
Name ID (Hex) Description Source Default
Value
Operation Effect
NTP Server
Response
Timeout
The unit could not
contact the NTP Server.
The time/date will drift
over time.
Base
Unit
Warning
Does not affect operation
but date and time could be
wrong with server.
Internal
Hardware
Issue
00000449
An Internal Hardware
Issue has occured. The
system may not function
properly.
Base
Unit
Minor
May not affect normal
operation but should be
investigated.
Host Build
Version
Mismatch
0000044A
Host software is not at
an officially released
version. Host function
may not be affected.
Base
Unit
Minor
Unit may operate correctly
but has an invalid build in.
Should be replaced with a
valid build as soon as
possible (unless a debug
build).
Host Identity
Not
Programmed
0000044E
The host identity could
not be read correctly.
Base
Unit
Major
Unit may operate but has
an internal error and should
be investigated.
Uncontrolled
release
0000044F
This combination of host
and option card software
is not officially
supported. This may
lead to unexpected
behavior.
Base
Unit
Minor
Unit may operate correctly
but has an invalid build in.
Should be replaced with a
valid build as soon as
possible (unless a debug
build).
No identity
license
00000450
This unit has not been
licensed with an identity.
Base
Unit
Critical
Unit may operate but has
an internal error and should
be investigated.
Lost Contact
With Peer
This unit is not able to
contact its redundancy
peer. Check that peer IP
address is correct,
control network
connections are correct
and that peer working
correctly.
Base
Unit
Major
The output should be
maintained by primary
or/and secondary – MGP
will stop dual streaming
Unit
Unavailable
This unit has been
configured to be
Unavailable. This means
it will not take part in the
1 + 1 redundancy group.
Base
unit
Critical
Service will continue but
this is a severe warning
that 1+1 will not operate if
required.
2/1553-