Alarm Lists
2/1553-FGC 101 1400 Uen B
E-14
Name ID (Hex) Description Source Default
Value
Operation Effect
Conflicting
Status
The Primary and
Secondary
Active/Passive status
values are in conflict
and cannot be resolved
automatically. Both units
are either Passive or
Active. This can occur if
power is lost, or the
control connection
between the units fails.
To clear this condition
use the Set Primary
Active or Set
Secondary Active
buttons on the
Standalone 1 + 1
Redundancy
configuration settings.
Base
Unit
Critical
An event has occurred that
probably interrupted service
for a period and now the
units need to be reset to a
know status.
No data
available for
Input
Transport
Stream
00000501
-
0000050A
Both Primary and
Backup Input Transport
Streams have failed.
Base
Unit
Critical
The data on both inputs
have failed and will cause a
loss of service.
Input
Transport
Stream
running on
Backup
00000511
-
0000051A
Primary Input Transport
Stream has failed.
Base
Unit
Warning
A switch has occurred to
back up input. The cause
for this should be
investigated.
MGP Failure
Failed to go online,
previous online device
preventing transmission.
Base
Unit
Major
Previous device is still on
line and MGP has stopped
this unit from going on line.
MGP Collision 00000492
Potential duplicate
transmission detected.
Base
Unit
Major
Service should be
maintained but there seems
to be inconsistent
messaging in the system.
Needs to be investigated.
MGP Spurious 00000493
Spurious MSM packet
detected.
Base
Unit
Minor
Service should not be
affected but an unexpected
message appeared. If this
continues it should be
investigated.
Reflex
Operation
Compromised
00000693
Unexpected scenario.
Some video
components will be
stuck at a low bit rate.
Base
Unit
Major
This should not happen in
normal operation. Unit
should be rebooted to
recover. If the alarm
persists, contact Customer
Support.