Ericsson SPR1100 Operations Instructions Page 287

  • Download
  • Add to my manuals
  • Print
  • Page
    / 300
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 286
Alarm Lists
Name ID (Hex) Description Source Default
Value
Operation Effect
License
Expired
The 1 + 1 redundancy
backup license has
expired. The secondary
unit is not able to act as
a redundant spare. The
video data outputs of the
secondary unit have
been disabled. Contact
support to renew the
license.
Base
unit
Critical
The time limit on the
secondary unit has expired
and the services have been
turned off. Renew license
and bring primary unit back
on line.
Redundancy
Parameters
Unavailable
The redundancy
configuration
parameters have not
been configured
correctly (either on this
unit or the peer unit).
Base
Unit
Major
This should be a set up
alarm. The units are not set
up correctly for redundancy
– please check.
Conflicting
Roles
The primary and
secondary Device
Roles are in conflict. For
a valid redundancy
group there must be
exactly 1 unit with
Primary role an 1 unit
with Secondary role.
Check the Device Role
setting on your primary
and secondary units.
Base
unit
Major
This should be a set up
alarm. The units are not set
up correctly for redundancy
– please check.
Conflicting IP
Addresses
The primary and
secondary IP address
configurations are in
conflict. Ensure that the
Peer IP Address setting
on each unit is correctly
configured with the
control IP address of its
peer.
Base
Unit
Major
This should be a set up
alarm. The units are not set
up correctly for redundancy
– please check.
2/1553-
FGC 101 1400 Uen B
E-13
Page view 286