B.6.2 DC Input
This equipment is suitable for voltages of -40 V to -60 V. Correct polarity must be
observed.
Table B.11 DC Power Supply Specification
Item Specification
Rated voltage For Connection to -48 V supplies only.
(PSU input tolerance -40 V DC to -60 V DC). Correct
polarity must always be observed.
Rated current 9 A.
DC input connector details
For connection to the 48 V input connector, the following
parts from AMP or Molex should be used:
AMP Universal MATE-N-LOK
Housing: AMP no. 1-480700-0
Female terminal (3 per housing): AMP no. 926901-1
Molex MLX
Housing: Molex no. 50-84-1030
Female terminal (3 per housing): Molex no. 02-08-1002.
Power consumption 40 W – 350 W (depending on options fitted).
B.7 Compliance
1
B.7.1 Safety
This equipment has been designed and tested to meet the requirements of the
following:
EN 60950-1 European Information technology equipment - Safety.
IEC 60950-1 International Information technology equipment - Safety.
UL 60950-1 USA Information technology equipment - Safety.
1
The version of the standards shown is that applicable at the time of manufacture.
2/1553-
FGC 101 1400 Uen B
B-10