Ericsson SPR1100 Operations Instructions Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 300
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
Introduction
1.3.6 Table Processing
The SPR1100 generates the following tables:
PAT (Program Association Table).
PMT (Program Map Table).
SDT (Service Descriptor Table).
CAT (Conditional Access Table).
The SPR1100 will not pass through or process any other tables and these, including
the following, will be dropped:
EIT (Event Information Table).
NIT (Network Information Table).
SDT (Service Description Table).
1.3.6.1 Multiple PMTs in a PID
The SPR11
00 can support incoming MPTSs where the PMTs for the services are in
one PID.
1.3.7 Transport Streams
1.3.7.1 Unicast Input
An incoming unicast is detected by its IP address. If the IP address is outside the
reserved multicast address range, it is treated as a unicast.
1.3.8 Redundancy
The SPR1100 supports the following redundancy modes:
Input source redundancy.
Input port redundancy:
- Active active 1+1 redundant pair or
- 2 inputs adding together i.e. each receiving different streams.
Output Port redundancy:
- Active standby only.
- No active active yet.
Chassis redundancy:
- 1+1 active standby.
2/1553-FGC 101 1400 Uen B