Stream Processing and Networking
Parameter Description
message. The options are: Start Messages Only, i.e. only
system start up events. Fail and Start Messages only i.e.
start-up events and critical alarms. All traps i.e. start-up
events and all alarms and warnings.
6.10 XPO
The unit supports an HTTP/HTTPS interface (see Appendix B, Technical
Specification for further details) that is XPO2 (the name given to the second
generation
Ericsson standard for web pages and additional supporting interfaces)
compliant for configuration and status monitoring. At least three simultaneous
HTTP/HTTPS sessions can be supported. HTTP access can be enabled or
disabled.
Individual parameters can be controlled via XPO2. It does not require the complete
XML configuration to be sent to change a single parameter.
Note: The legacy XPO standard is not supported.
The web pages provide a service orientated control menu structure.
6.11 Clock & Timing
The Host Controller card has a real time clock, which is battery powered when the
chassis is unpowered, so that the time and date is maintained. This clock is
designed to be accurate to ±1 minute per month. The battery is capable of powering
the clock for over two years.
6.11.1 User Configurable Parameters
The user configurable parameters associated with the clock are defined below
Table 6.8 Clock Configurable Parameters
Parameter Values Description
Local Time hh:mm:ss Current local time in hours minutes and seconds
Local Date dd:mm:yyyy Current date in day month and year
2/1553-FGC 101 1400 Uen B
6-29