Preventive Maintenance and Fault-finding
8.5.3 Power Supply Problems/Unit Not Working
If the unit Status LED is unlit, fault-find the problem as detailed in Table 8.2.
Table 8.2 Status LED Unlit Fault-finding
Step Action If Result of Action is
Yes…
If Result of Action is
No…
1
Confirm Status LED. Is
the unit working but the
display inactive?
If the unit is clearly
working normally then
the front panel may be
at fault. Call a Service
Engineer.
Proceed to next step.
2
Check Power Source.
Connect a known-working
piece of equipment to the
power source outlet. Does
it work?
The problem lies within
the unit or power cable.
Proceed to next step.
The problem lies with the
power source. Check
building circuit breakers,
fuse boxes, etc. If
problem persists, contact
the electricity supplier.
3
Check Power Cable and
Fuse. Unplug the power
connector from the unit
and try it in another piece
of equipment. Does it
work?
The problem lies within
the unit. Proceed to next
step.
The problem lies with
either the cable itself, or
with the fuse in the plug.
Replace the fuse or try to
substitute another cable.
4
Check PSU Module(s)
and Fuse(s). Ensure the
power connector is
unplugged. Remove the
fuse from the rear panel
connector and inspect it.
Has the fuse blown?
Replace the fuse with
one of the correct type
and rating (see Annex B
Technical Specification).
If the PSU still does not
work, unplug the power
cable and call a Service
Engineer.
Possible problem with the
PSU module. Call a
Service Engineer.
8.5.3.1 Fuse Replacement
Fuses are held in integral fuse carriers at the AC power inlets at the rear panel.
Note: Refer to Technical Specification for more information about the fuse.
Warning!
Before replacing the rear panel fuses, disconnect the unit from the supply. Failure to
do this may expose hazardous voltages. Unplug the unit from the local supply
socket.
To replace the AC power fuse(s):
2/1553-FGC 101 1400 Uen B
8-8