Ericsson SPR1100 Operations Instructions Page 122

  • Download
  • Add to my manuals
  • Print
  • Page
    / 300
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 121
Web GUI Control
Figure 5.45 System > Standalone 1+1 Redundancy Web Page
The following fields are available on this page:
Device Role Role this unit takes in the redundancy group.
Peer IP Address Address of the peer unit within the redundancy group.
ICMP Ping Period – The period between consecutive ICMP pings.
RPC Ping Period – The period between consecutive RPC pings.
Availability – Specifies a preference as to whether this unit should participate in
the redundancy group. If a secondary backup unit is unavailable, then an
automatic redundancy switch to that unit will not take place. If a primary (main)
unit is unavailable then an automatic switch to the secondary unit may occur
(depending on the state of the secondary unit). This is achieved through raising
a critical alarm on the unavailable unit.
Primary Device Section
IP Address IP address of the Primary unit.
Status Current unit status. Active indicates that all the unit’s data outputs are
enabled while Passive indicates that they are disabled.
Last Updated – The time at which the last configuration change was made.
IMPC Ping Status – Displays whether this unit can ping its peer.
RPC Ping Status – Displays whether this unit can ping its peer.
Alarm Status – Status of Primary unit alarm.
Secondary Device Section:
IP Address IP address of the secondary unit.
2/1553-FGC 101 1400 Uen B