Chapter 3
3. Press Save to save the new settings or Edit to abandon the operation and
return to the current setting.
4. If YES is saved, inputs will be reset and the unit rebooted immediately.
3.5.1.4.2 1.4.2 Reset All Incl IP & Reboot
To access this function, press the T (Down) key. The following screen is displayed
and the Edit key is lit:
FACTORY |RESET ALL INCL IP & REBOOT
1.4.2 |NO
To enable/disable the reset including IP network parameters:
1. Press the Edit key. The cursor appears below the NO.
2. Use the S (Up) and T (Down) keys to toggle between YES and NO.
3. Press Save to save the new settings or Edit to abandon the operation and
return to the current setting.
4. If YES is saved, inputs will be reset and the unit rebooted immediately.
When all necessary operations have been performed, press the W (Back) key to
return to the Factory sub-menu.
3.5.1.5 1.5 Front Panel (FP)
To view the Lockout Front Panel (FP) Access menu, press the T (Down) key. The
following screen is displayed:
FP |LOCKOUT FRONT PANEL ACCESS
1.5 | >
3.5.1.5.1 1.5.1 Front Panel Lockout
To access the front panel lockout function, press the X (Forward) key.
Note: When enabled (set to ON) this function will disable the front panel controls
preventing further operation of any of the keys. The LCD will still continue to
display summary information screens. This feature may be disabled again
using the front panel controls.
The following screen is displayed:
FP |FRONT PANEL LOCKOUT
1.5.1 |OFF
To enable/disable front panel lockout:
1. Press the Edit key. The cursor appears below the OFF.
EN/LZT 790 0005 R1A