Communications systems built to drive business ahead
MD Evolution 8.1
Product News
25
PN 06:16 Rev A 2006-10-20
Created by ESF/KEP/MA Francois Vaillant
- No new version of the CTI-Link server, when supported by a PC. The CTI-
Link server is in version 1.0.009 and the CTI-Link client in version 1.0.011.
The old CD-ROM media kit CTI-Link is no more for sales. The software is
available on the Ericsson web sites.
5.6 HW and SW compatibilities
This section describes the required hardware and software for introducing a new
V8.1 service on an installed system. Refer the various compatibility tables
updated in version 8.1 in the MDE Administration CD-ROM8.1.
5.6.1 Hardware issue with new version 8.1
The version 8.1 includes all xMV optional services, the same available with
software XMV5.2.1/ XIP5.2.1. The version 8.1 can be implemented on any
installed system already in versions 7.0/7.1/8.0A/8.0C without hardware change.
Nevertheless service dimensioning can require new boards: either line boards or
CMV/SMV/EMV board. Afterwards verify the required protection software
licenses.
The installed system is in version <8.1 and a new V8.1 service shall be
implemented:
Read first the description of the new service that includes the pre-requisites:
hardware, software and, if required, software licenses.
Then refer to the compatibility tables to check hardware and software compatibility
with version V8. and xMV5.2.1. This is what is described hereafter.
5.6.2 Upgrading the CPU hardware and software with V8.1
Follow the described steps with the compatibility tables:
Select the table “Hardware compatibilities according to software versions” for the
installed system: MDE-M, MDE-XL or MD34/MD35/MD36. Enter the last line
version R8.1 and read the compatibility with the CPU installed board. When not
compatible (ex: CPJ3 R-state<G) the CPU board shall be changed. Then verify
that version 8.1 is compatible with all installed boards (version 8.1 knows the
boards by their signature).
The CPU board shall be changed. Then verify that CPJ6/MPM2 is compatible with
the installed backplane and power supply. Refer to table “Hardware
compatibilities according to CPU configuration”. For MDE-XL, MPM2 is not
compatible with backplanes SFP/MFP/MFE. For MDE-M CPJ6 is delivered with
the cabinet (no problem of backplane) but verify the power supply (CPJ6 is not
compatible with CCS1/CCS2).
Then verify the CPU compatibility with the other installed boards.
The CPU is changed. CPJ6/MPM2 could be not compatible with some installed
boards. Example: CPJ6 is not compatible with CAP (CAP2 shall be used); but
CPJ6 is compatible with CZI.
Whatever the CPU board is, verify the firmware on the installed boards to offer the
required new service. Example: the CLIP service requires a firmware upgrading