MD Evolution 8.1
Product News
18
PN 06:16 Rev A 2006-10-20
Created by ESF/KEP/MA Francois Vaillant
The CCS4-S board provides the -40 Volts source required for remotely power feeding
the radio DECT base stations connected through the system CRE2 and CRO boards.
Voltages CCS4-S Power
+ 5 Volts DC 4.5 A ) 4.5 A
+ 3 Volts DC 1.5 A ) Cumulated
- 5 Volts DC 0.3 A
- 40 Volts DC 2 A
63 Veff – 20/25/50
Hz
(+15Vdc-15 mA)
0.75 A selection of
the ringing
frequency
done by switch
Finally, when an internal or external back-up battery is installed, CCS4-S also provides,
in parallel to the system consumption, the current required to permanently load and,
when necessary, recharge the back-up battery that is then mounted in parallel.
CCS4-S board is sized to meet the maximum consumption of a MD Evolution M/ MD
Evolution Mi/ EBN system which is about some 100 Watts. The CCS4-S board has a
MTBF greater than 200,000 hours.
The above voltage dimensioning satisfies all maximal configurations of a system,
whether it is only equipped with wired stations, or DECT wireless base stations. The
rating makes it capable to additionally support the consumption of all 8 radio base
stations that can be connected to the system. And CCS4-S board allows to
simultaneously ring up to 9 analog stations.
CCS4-S description
CCS4-S uses a natural convection for cooling purposes. In the MD Evolution Mi 19-
inch rack, an external fan, part of the cabinet, is connected to CCS4-S.
Optional back-up battery
A back-up battery is not strictly required for the correct operation of the system. It is
however recommended in order to ensure a given system operating autonomy in case
of a mains failure; especially should the mains source not fully reliable. Upon a mains
failure, when the system is fed from the internal or external back-up battery, when
installed, complete system operation autonomy is ensure, including ringing generator.
In practice, the MD Evolution M/ EBN (wall mounted) basic system cabinet supply
includes a 12 V / 7 Ah battery of a sealed lead-acid type (type YUASA NP 7-12 or
equivalent), that is intended to be directly mounted inside the system cabinet. In case
of mains failure, depending on the hardware system configuration, the battery provides
a system operating autonomy from 0.5 to 2 hours.