Communications systems built to drive business ahead
MD Evolution 8.1
Product News
19
PN 06:16 Rev A 2006-10-20
Created by ESF/KEP/MA Francois Vaillant
Alternatively, a greater capacity 12 V / 12 Ah or 24 Ah battery of a sealed lead-acid
type (type YUASA NPL 12-12 or YUASA NPL 24-12 respectively), not supplied, may
be installed externally to the system cabinet to ensure longer system autonomy in
case of a mains failure.
For the MD Evolution Mi/ EBN (rack version) any 12V battery may be installed
externally to the system cabinet.
CCS4-S Settings
The only setting allows selection of the ringing frequency for the analogue stations: 20,
25 or 50Hz. A switch, on the left side of the CCS4-S board is accessible when the
system cabinet is open.
CCS4-S cabling
The CCS4-S board is connected to the CPJ5/CPJ6 board through a power supply flat
cable, provided.
The CCS4-S board is connected to the 230 Volts - 50 Hz mains source using a 3-wire
230 Volts + Ground power supply cord, which is 3 meters long. Three types of power
cord are available (please check the Ordering Information whether the correct power
cord is included in the ordered system package):
o one compliant to EU standards (always provided with the
CCS4-S),
o one compliant to GB standards,
o and one compliant with USA and Canada standards.
The CCS4-S board can be also connected to the optional back-up battery:
o For connection of the 12 V - 7 Ah internal battery (MD
Evolution M/ EBN wall mounted version), the two battery
power wires are provided and directly connected to CCS4-
S board.
o For connection of an external battery, the above power
wires may be replaced by longer (maximum: 2 meters) 2.5
mm
2
cross section power wires, not provided.
5.3 New ISDN PRA protocols T1 for North American
markets
This enhancement applies only to MD Evolution M/Mi systems.
Previously the MD Evolution was only supporting the ISDN PRA signaling
compliant with the European standard ETS 300 403-1. In Europe, it is the E1
interface that has 32 time slots (2 Mbits/s). Voice codec is in A-law.