Using the TT1222 with the Director System
E.2.6 Force Service Selection
Force’s the receiver to select a different service on the same frequency and LNB
input. Only the service selection is required for this command.
If the service fails to decode, the receiver will tune to the Emergency Home Carrier
if valid.
E.2.7 Set Emergency Home Carrier
Set the service parameters to use in the event of decode failure. Where the current
service selection fails to decode and the receiver is in OAC control mode then if the
Emergency Home Carrier has been defined, the receiver will tune to this service
after a specified timeout. The timeout for Emergency Home Carrier is defined when
sending this command.
Setting the Emergency Home Carrier allows a failure situation to be recovered,
particularly since the receiver can only accept Director commands from a carrier that
contains them.
E.2.8 Set Relays
Switches the general-purpose alarms. This command does not affect the summary
alarm relay.
E.2.9 Local Lockout
Locks out the LOCAL CONTROL mode but status information can still be viewed. All
Director commands are functional. The Receiver can be unlocked locally using a
PIN number or over-air using Allow Local Access.
E.2.10 Abort NCP Command
Aborts commands that have been sent but not executed. When a command is
received which has an expired execute time, it is acted on immediately.
EN/LZT 790 0002/2 R1A