Alarm Categories and Conditions
Alarm
Category
Contents
TDT not
present
No data is received on
the TDT PID.
Check input
signal and verify
source.
A
VCT not
present
No data is received on
the VCT PID.
Check input
signal and verify
source.
A
STT not
present
No data is received on
the STT PID.
Check input
signal and verify
source.
A
D.5 Config Alarms
The config alarms contain alarms regarding the mismatches between present
hardware, software and license keys, and the overall health of the hardware.
Table D.9: Hardware Configuration Related Alarm Categories and Conditions
Alarm
Category
Contents
Alarm Description Remedy Default
Init fail
General initialization
failure.
Contact Ericsson
Customer Help
Desk
A
Cfg. Not
supp
The configuration
defined by the
configuration word could
not be supported.
A
Config alarms:
HW err.
The hardware check
during initialization
failed.
A
EN/LZT 790 0002/2 R1A
D-9