TROUBLESHOOTING PROCEDURES
TEST PROCEDURESTEST PROCEDURES
STEP 2
USABLE SENSITIVITY
(12 dB SINAD)
If STEP 1 checks out properly, measure the receiver sensitivity as follows:
A. Apply a 1000 microvolt, on frequency signal modulated by 1000 Hz with 3.0 kHz deviation to A301-J1.
B. With Function Switch on Distortion Analyzer set to VOLTMETER position, adjust volume control for 1.0 Watt (2.83 VRMS
across 8 ohm load). Again, verify that audio output is nulled when Function Switch is set to DISTORTION position.
C. Place the RANGE switch to the SET LEVEL position (filter out of the circuit) and adjust the input LEVEL control for a
+2 dB reading on a 30% range.
D. While reducing the signal generator output, switch the FUNCTION control from SET LEVEL to the DISTORTION until
a 12 dB difference (+2 dB to -10 dB) is obtained between the SET LEVEL and DISTORTION positions (filter out and filter
in).
E. The 12 dB difference (Signal plus Noise and Distortion to noise plus distortion ratio) is the "usable" sensitivity level. The
sensitivity should be less than rated 12 dB SINAD specifications with an audio output of watt across the 8.0 ohm load.
F. Leave all controls as they are and all equipment connected if the Modulation Acceptance Bandwidth test is to be performed.
SERVICE CHECK
If the sensitivity level is more than the rated 12 dB SINAD specification, check the alignment of the RF stages as directed in the
Alignment Procedure, and make the gain measurements as shown on the Troubleshooting Procedure.
STEP 3
MODULATION ACCEPTANCE
BANDWIDTH (IF BANDWIDTH)
If STEPS 1 and 2 check out properly, measure the bandwidth as follows:
A. Set the Signal Generator output for twice the microvolt reading obtained in the 12- dB SINAD measurement.
B. Set the RANGE control on the Distortion Analyzer in the SET LEVEL position (1000-Hz filter out of the circuit), and
adjust the input LEVEL control for a +2 dB reading on the 30% range.
C. While increasing the deviation of the Signal Generator, switch the RANGE control from SET LEVEL to distortion range
until a 12- dB difference is obtained between the SET LEVEL and distortion range readings (from +2 dB to -10 dB).
D. The deviation control reading for the 12- dB difference is the Modulation Acceptance Bandwidth of the receiver. It should
be more than ±7 kHz.
SERVICE CHECK
If the Modulation Acceptance Bandwidth test does not indicate the proper width, make gain measurements as shown on the
Receiver Troubleshooting Procedure.
STEP 1 - QUICK CHECKS
TEST SET CHECKS
These checks are typical readings measured with Test Set Model 4EX3A11 in the Test 1 position, or Model 4EX8K12 in the
1-Volt position.
SYMPTOM PROCEDURE
NO SUPPLY VOLTAGE
Check power connections, continuity of supply leads. Check fuse
and replace if blown. Check receiver for short circuits.
NO REGULATED 10-VOLTS
Check the 12 Volt supply. Then check 10 Volt regulator circuit.
(See Troubleshooting Procedure for 10 Volt Regulator).
LOW IF READING
Check supply voltages and then check oscillator readings at
P904-1 & -2 as shown in STEP 2.
Make SIMPLIFIED GAIN CHECKS from Mixer through
Limiter Detector stages as shown in STEP 2.
LOW OSCILLATOR/MULTIPLIER READINGS
Check alignment of Oscillator/Multiplier chain. (Refer to Front
End Alignment Procedure).
Check voltage readings of Oscillator/Multiplier chain (Q401,
Q402, Q403).
LOW RECEIVER SENSITIVITY
Check Front End Alignment. (Refer to Receiver Alignment
Procedure).
Check antenna connections, cable and antenna switch.
Check Oscillator injection voltage.
Check voltage readings of IF Amplifiers.
Make SIMPLIFIED GAIN CHECKS (STEP 2).
406-512 MHz MSTR II RECEIVER
METERING READING READING WITH- TEST
POSITION WITH NO 10 MICROVOLTS POSITION
SIGNAL IN (UNMODULATED)
A (FM DET) Approximately Test 1
0.38 VDC (or 1 Volt)
B (IF Amp) 0.1 VDC
C (Mult-1) 0.4 VDC
D (Mult-2) 0.4 VDC
F (Mult-3) 0.1 VDC
J (Reg. +10 Volt at +10 VDC
System Metering
SYMPTOM CHECKS
Con’t.
LBI-38505 LBI-38505
8