Ericsson LBI-38505A Specifications Page 1

Browse online or download Specifications for Receiver Ericsson LBI-38505A. Ericsson LBI-38505A Specifications [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
LBI-38505A
(Supercedes LBI-30025)
TABLE OF CONTENTS
RF ASSEMBLY, MIXER AND
REFILTER BOARD . . . . . . . . . . . . . LBI-30032
(DF1107)
OSCILLATOR/MULTIPLIER
BOARD . . . . . . . . . . . . . . . . . . . . LBI-30029
(DF1106)
IF AUDIO AND SQUELCH
BOARD . . . . . . . . . . . . . . . . . . . . LBI-38507
Maintenance Manual
MASTR
®
II
BASE STATION
406-512 MHz RECEIVER
Ericsson Inc.
Private Radio Systems
Mountain View Road
Lynchburg, Virginia 24502
1-800-528-7711 (Outside USA, 804-528-7711) Printed in U.S.A.
ericssonz
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Maintenance Manual

LBI-38505A(Supercedes LBI-30025) TABLE OF CONTENTSRF ASSEMBLY, MIXER AND REFILTER BOARD . . . . . . . . . . . . . LBI-30032

Page 2 - SPECIFICATIONS*

TROUBLESHOOTING PROCEDURESSQUELCHED UNSQUELCHEDNOISE SQ OUTPUT U605-20.2 VDC 9.9VCAS U605-10.1 VDC 9.9VRX MUTE U605-140.2 VDC 9.9VRUS U605-130.2 VDC 4

Page 3 - MAINTENANCE

TROUBLESHOOTING PROCEDURES406-512 MHz MASTR II RECEIVERLBI-38505 LBI-3850510

Page 4 - MODIFICATION INSTRUCTIONS

406-512 MHz MASTR II RECEIVERTROUBLESHOOTING PROCEDURESLBI-38505 LBI-3850511

Page 5

Copyright © May 1990, Ericsson GE Mobile Communications Inc.TABLE OF CONTENTSPageSPECIFICATIONS . . . . . . . . . . . . . .

Page 6

DESCRIPTIONMASTR II Base Station, 406 to 512 megahertz receiversare single conversion, superheterodyne FM receivers designedfor one-through eight-freq

Page 7 - ALIGNMENT PROCEDURES

To remove the IF Filter board from the radio:1. Remove the eight screws (E) holding the IF Filter bottomcover.2. Remove the six screws (F) holding the

Page 8 - TEST PROCEDURES

FRONT END ALIGNMENTEQUIPMENT REQUIRED1.Test Set Models 4EX3A11, 4EX8K12, or 20,000 ohms-per-Volt multimeter with a 1 Volt scale.2.A 406-512 MHz signa

Page 9 - STEP 1 - QUICK CHECKS

406-512 MHz MASTR II RECEIVERICOM FREQUENCY ADJUSTMENTFirst, check the frequency to determine if any adjustment is required. The frequency measurement

Page 10 - LBI-38505 LBI-38505

ALIGNMENT PROCEDURESCOMPLETE RECEIVER ALIGNMENTEQUIPMENT REQUIRED1.Test Set Models 4EX3A11, 4EX8K12, or 20,000 ohms-per Volt multimeter with a 1- Volt

Page 11

TEST PROCEDURESThese Test Procedures are designed to help you to service areceiver that is operating---but not properly. The problems en-countered cou

Page 12

TROUBLESHOOTING PROCEDURESTEST PROCEDURESTEST PROCEDURESSTEP 2USABLE SENSITIVITY(12 dB SINAD)If STEP 1 checks out properly, measure the receiver sensi

Comments to this Manuals